A water calculation takes a minute. Gathering the information for it is where the time goes, and where most errors start. November is when January starts get finalised, so it is the right moment to get the fittings data right before anything is ordered.
Here is what you need in hand before you run a Part G calculation for a new dwelling in England.
Before anything else, confirm whether the dwelling is held to the standard 125 litres per person per day, or the tighter 110 that many planning authorities impose as a condition.
Approved Document G asks for the manufacturer's declared water consumption for each fitting. A description like "dual flush WC" or "thermostatic shower" is not enough. You need:
Some features mean the simple fittings approach is not available and the full calculation must be used:
Flag these early. They are easy to miss in a schedule and they change the route to compliance.
For straightforward dwellings, Approved Document G sets out a fittings approach. If every fitting is at or below these values, the dwelling meets the target:
|
Fitting |
125 l/p/d |
110 l/p/d |
|---|---|---|
|
WC |
6/4 litres dual flush or 4.5 litres single flush |
4/2.6 litres dual flush |
|
Basin taps |
6 l/min |
5 l/min |
|
Shower |
10 l/min |
8 l/min |
|
Bath |
185 litres |
170 litres |
|
Kitchen sink taps |
8 l/min |
6 l/min |
|
Dishwasher |
1.25 l/place setting |
1.25 l/place setting |
|
Washing machine |
8.17 l/kg |
8.17 l/kg |
The calculation route gives more flexibility. A slightly bigger bath can be balanced by a more efficient WC, for example, as long as the total stays under the target.
Keep the manufacturer data sheet for every fitting in the calculation. If building control queries a figure, or a fitting is swapped on site, the data sheet is how you prove the number.
Can I use the fittings approach for every dwelling? No. If the dwelling has a water softener, a waste disposal unit or water reuse, the full calculation must be completed.
What if I do not know the exact product yet? Run the calculation on the specification you intend to use, then lock the flow rates and flush volumes into the schedule so substitutions cannot quietly change the result.
Does this apply in Wales? Wales sets its own targets, so check the Welsh guidance for projects there.
This article is general guidance and not a substitute for advice on your specific project. Always confirm requirements with your building control body.
Posted In:Water Useage, Water Calculations,